User manual

AP 230 USER MANUAL 5
RESIDUAL RISKS OF THE SYSTEM
WARNING: The system, during its working cycle, presents some mecha-
nical hazards, that can be the origin of injuries due to
mechanical actions of the machine parts. Do not access
into the interdiction zone before carefully following the
"SAFETY MODE FOR THE MAINTENANCE" procedure as
described at points 1 and 2 of paragraph 8.1.
Such mechanical hazards can be evaluated as
follows:
- Crushing hazard
- Cutting/Severing hazard
With reference to the above mentioned hazards,
it is compulsory to follow the here below safety
measure:
- It is necessary to exclude the interdiction zone all around the application sy-
stem with deterrent and/or hamper device fixed on the floor, such as for exam-
ple yellow/black stakes joint together with a protection chain of the same colour
having a floor height of 100 cms. minimum and safety distance of 1.4 m. from
the applicator plate. Warning boards indicated the interdiction zone and kind
of hazard will be hung on the chain that exclude the interdiction zone.
- The emergency stopping device, placed outside the interdiction zone, is a safety
device that activates automatically by stopping the system in case of loss of
tension or loss of pressure on the pneumatic supply, blocking the unexpected/
unintended start up of the system when the supply sources are returned. Re-start
will be possible only by actioning the buttons on the emergency stopping device
by the operator.
- All personell, that can occasionally have access to the interdiction zone, have
to be instructed on the residual risk and on the no-entrance on the interdiction
zone. It is particularly reccommended to instruct the personnel on the residual
risks and on the prohibitions, and to follow carefully the "SAFETY MODE FOR
THE MAINTENANCE" procedure before accessing into the interdiction zone.
NO