12.2 - APPLICATOR ENABLES
Through the front panel it is possible to enable the applicator following a standard
working cycle that takes an up-down lead time of 0.9 sec.
Following instruction on paragraph 12.1 set the machine in configuration mode, than
press key "HEAD LIFT" (the corresponding led lights). In
that way the printer is in operating mode and you can set-up
the parameters concerning command "N".
Than press together keys "RIBBON ECONOM" and "HEAD LIFT".
In this way the applicator is enabled and the printer will eject a test label that will
report the standard working cycle data of the applicator (N-199000), that takes an
up-down lead time of 0.9 sec.
To disable the applicator follow the same procedure, pressing key "THERM
TRANSF" instead of key "RIBBON ECONOM" following the sequence:
12.3 - ENABLE OBJECTS SENSING PHOTOCELL
Through the front panel you can enable the objects sensing photocell and the
applicator working mode.
Following instruction on paragraph 12.1 set the machine in configuration mode, than
press key "HEAD LIFT" (the corresponding led lights). In
that way the printer is in operating mode and you can set-up
the parameters concerning command "K".
+
+