User manual

AP 230 USER MANUAL 34
11.3 - SETTING THE DIRECTION AND AIR JET STRENGTH FROM THE
NOZZLES.
Now set the direction and air jet strength so that the air flow from the nozzles located
on the application assembly allowing the label to be held on the plate uniformely.
Generally the applicator is supplied already ready to operate with a specified label
format, the table below shows how to enable/disable the nozzles to operate with
label formats different from the one supplied.
Therefore when using small labels (50 mm
high maximum) the 2nd and 3rd nozzels
will be removed and replaced with the
supplied M 5 screws.
When using medium labels (80 mm high)
the 3rd nozzle will be replaced with a M 5 screw.
When using large labels (over 80 mm high) all three nozzles will be used.
Now we proceed with air jet strength by using
a flat screwdriver through the hole on the front
bracket and by its turning left/right wise that
allows to open or close the flow regulator in
order to deliver a greater or smaller amount of
air, as indicated on picture 28 on your left.
1° NOZZLE
Toward the printer, for small labels ( 50 mm high
maximum)
2° NOZZLE Middle, for medium labels ( 80 mm high)
3° NOZZLE External, for large labels (over 80 mm high)
PICTURE 28 - AIR JET STRENGTH
ADJUSTMENT.