8 - EMERGENCY STOPPING DEVICE
The system AP 230 is equipped with an emergency stopping device, it allows to take
under control both the electrical and pneumatic supply by stopping the system in
case of loss of pressure on the pneumatic supply or in case of loss of voltage on the
electrical power supply.
The Emergency stopping device is composed of:
1 - Compressed air entrance
2 - Power supply entrance
3 - Compressed air exit
4 - Power supply exit
5 - Emergency red button
6 - Re-start green button
The emergency stopping device has to be compulsory placed outside the
interdiction zone created around the applicator and in a place of easy access
and visible position by the operator so that to be sure of the non-presence of
personnel exposed to risk.
The automatic block of the system allows that it can not automatically re-start in case
both of loss of air-pressure or loss of voltage.
In this case the operator after the neccessary check, shoud unlock the red button
by turning it following the sense of the arrow marked on it and press the green button
to re-start the system and send the text of the label.
WARNING: In case the operator has to access the interdiction zone,
follow carefully the procedure described on paragraph 8.1.