User manual

AP 230 USER MANUAL 20
6 - ELECTRICAL AND PNEUMATIC CONNECTIONS
6.1 - ELECTRICAL CONNECTION
AP 230 system has to be connected to the power supply , through the emergency
stopping device that has to be
fixed outside the interdiction
zone following the instructions
below:
1 - Prepare a feeding cable
with an adequate section not
less than 3 x 1,5 mm, where
from applicator side will be
mounted the dedicated female
connector that will be inserted
into the plug on the rear panel of
the printer.
2 - On the opposite pole of
the cable, mount the dedicated
spindle and insert it into the sup-
ply plug with protected contacts that is mounted on the emergency stopping device.
3 - Insert the female connector of the supply cable into the proper plug mounted
on the emergency stopping device.
4 - Connect the spindle of the power cord to an appropriate socket outlets with
following voltages:
220 VAC ± 10% 50/60 Hz
110 VAC ± 10% 50/60 Hz (as per require)
240 VAC ± 10% 50/60 Hz (as per require)
WARNING: Be sure that the power cord is connected to an electrial
installation with proper earthed.
Such electrical installation as per CEE safety rules.
PICTURE 15 - POWER SUPPLY
1
2
3
4