4.2 - WORKING PLACE
The AP 230 system can be easily installed according to the user’s various needs,
allowing label application either on the top and on the side of the package.
It is necessary to exclude the interdiction zone all around the application system with
deterrent and/or hamper device fixed on the floor, such as for example yellow/black
stakes joint together with a protection chain of the same colour having a floor height
of 100 cms. minimum and safety distance of 1.4 m. from the applicator plate.
Warning boards indicating the interdiction zone and kind of hazard will be hung on
the chain that exclude the interdiction zone.
The chain will be compulsory closed during
the working cycle of the applicator.
In the proximity of the interdiction zone, in
any case outside the area, will be installed
the emergency stopping device located in
easy access and visible position by the
operator so that to be sure of the non-
presence of personnel exposed to risk. It is
advisable to install the emergency stopping
device in a range from the applicator so
that cables and connecting pipes are not
longer than 5 meters.
WARNING: During the working cycle of the system, nobody should
enter the interdiction zone. Before accessing the interdiction
zone it is compulsory to follow all the procedures described
at paragraph 8.1.
PICTURE 5 - WORKING PLACE AP 230 .
SAFETY DISTANCE
INTERDICTION ZONE