Specifications

DATAPROCESS EUROPE S.p.A.
ST3xx ST4xx ST5xx
– PROGRAMMING MANUAL -
Pag.6
conditions, with labels and ribbon correctly installed, a test label will be printed (unless
deactivated in configuration). The PRINT indicator lights up during printing.
Note: Printing of the test label can be deactivated with the / $&% command.
4
Test label
The test label contains the following information:
ST314
E1.4 00000
1.
Printer model, ROM type (E = EPROM, F = flash memory), firmware version and se-
rial number.
2.
Printhead temperature, photo sensor sensitivity (label pass, end paper, end ribbon).
3.
Current date and time are printed in the grey area of the model.
4.
A dot map (useful in checking the print quality and alignment of the print head) with a
black area, a grey area, vertical and horizontal lines with different spacings.
5.
Current configuration parameters of the printer. The configuration parameters are
stored in the non-volatile memory of the printer.
>T Identification and configuration parameters of the memory
>S Label feed parameters
>B Serial interface parameters
>A Network address
*O Print orientation
>P Photo sensor sensitivity
P Sensitivity of label photo sensor currently selected
19 247 032 000
08:35:40 Ven 25-A
p
r-1997
>T314D10423792B583808100004390439 Ymax:297 mm. Mem:512 kb
>S6400104010100 >B28N1 >A00 >C/ >L000
>P120078093187240
P100H0290
G00000008N00000000
*
02
K1000J1510V08105700
PWM:701 – 21.50mV
$&%0000000000000000
HON : 0:05 #SWON: 8
#LP: 5 KP: 0.001
2
3
4
5
6
1