Specifications
DATAPROCESS EUROPE S.p.A.
ST3xx ST4xx ST5xx
– PROGRAMMING MANUAL -
Pag.53
The switch or the photocell are connected in this way if the signal is to synchronise with
the presence of the package (K1501 N-1990000 in un AP403).
If instead the synchronisation is to be with the removal of the label (K1100 N00010000 in
ST403) it is sufficient to replace in the cable point 2 with 8 and 3 with 7.
23.4
Applicator interface – only for ST4xx ST5xx
This port also has a “D” 9 pin female connector which is also on the rear of the printer.
The following table gives the connections:
1 GROUND
2 Input1
3 Output1
4 Input2
5 Output2
6 Input3
7 Output3
8 Input4
9 +12VDC (500mA max)
23.5
Rewinder interface – only for ST4xx ST5xx
1 Not connected
2 Input synchronism for cutter
3 GROUND
4 Output rewinder motor 14VDC Max 2A