Specifications

DATAPROCESS EUROPE S.p.A.
ST3xx ST4xx ST5xx
– PROGRAMMING MANUAL -
Pag.35
With H0010 and the autocalibration the label will come set with the gap to 10 pass from
the sensor.
If the autocalibration is disabled H number represents the distance in pass between the gap
and the sensor.
The /H command must be followed by a 4 digit number, expressed in dots (values from
0000 to 9999). It defines the number of passes for the motor must still do after identifying
the gap.
17.27
/Iv...
/I0
/I1nv.. vmqqss
/I2ssssnnc.. c
/I3ssssthhhc.. ce
/I4ssssbbbllll
/I5ssssnncc.. c
The
/I
command is used to insert a variable field in the current position of the cursor.
The parameter
v
(values: from 0 to 5) after the
/I
command specifies the type of variable
field and determines the configuration of the parameters as follows:
17.27.1
/I0
Does not require other future parameters and is used to input the temperature of the
printhead expressed in degrees Centigrade (Celsius). The printhead temperature is read be-
fore every print and its value is updated automatically.
17.27.2
/I1nv.. vmqqss
Used to insert a numerator – a numeric field which updates itself.
n Number of digits in numerator
v
Starting value for numerator in
n
digits
m 0 increases the numerator and prints in black (°)
1 decreases numerator and prints in black
2 increases numerator and prints in white (^)
3 decreases numerator and prints in white
qq Value of increase or decrease
ss
Frequency of update i.e. every
ss
labels
(°): prints in black. Black in the case of direct thermal otherwise the colour of the ribbon
used when in thermal transfer.
(^): prints in white. If the numerator is superimposed on an object (line, box, barcode,etc)
all the parts superimposed will appear in white.
17.27.3
/I2ssssnnc.. c
This is used to insert a “remote” field of text, represented by the sequence
c.. c
, made up
by
nn
(2 digits, 01 to 99) characters which the external computer must send to the printer
every
ssss
labels printed (4 digits, 0001 to 9999).