Specifications

V140602E iBoot-DC Page 2
2. General Description
The iBoot-DC is a network attached, IP addressed, web controlled DC power switch. Anyone with a web
browser can access iBoot-DC to perform power On, Off or Power Cycle (Reboot or Power Burst). iBoot-
DC uses two levels of password for security.
iBoot-DC is compatible with DC voltages from 5 to 48VDC. Both Positive and Negative DC voltage
sources are supported. A simple Web browser interface makes it easy to control power from anywhere in
the world with a click of a mouse. iBoot-DC also supports Telnet for text commands, as well as
Dataprobe’s Exchange Protocol (DxP) for interfacing to a variety of Dataprobe products and custom
software development.
2.1. Uses for iBoot
Remote reboot of any device, routers, servers, kiosks, etc. The device to be rebooted need not be
network attached.
Secure sensitive devices by keeping them powered off when not in use. This prevents hackers from
seeing them at all times.
Power down equipment when not needed for power savings and to save on wear and tear.
Power up alert devices like sirens, lamps, messages; or control environmental system like heaters,
coolers pumps, etc.
2.2. Multiple Control Options
In addition to the Web control capabilities, iBoot-DC features several other means to operate automatically
or under computer control.
AutoPing: The AutoPing feature allows iBoot-DC to automatically detect failed equipment and perform a
timed reboot or other power control function (like turning on an indicator or siren). You set 1 or 2 IP
addresses to be periodically pinged. When iBoot-DC no longer detects a response from the address(es),
the programmed power control function is actuated.
Telnet: iBoot’s Command Line Interface (CLI) allows direct control and setup through Telnet.
Dataprobe Exchange Protocol: iBoot-DC supports the Dataprobe Exchange Protocol (DxP) This protocol
allows Dataprobe products to communicate across networks, and allows developers to design custom
applications to integrate iBoot-DC into custom applications. For more information about DxP, contact
Dataprobe Applications Engineering and Support.