Specifications

Page 6
Control and Status Page
Once the user is validated, the Control and Status is displayed. (Only one person can be connected
to the iBoot-G2 at a time.)
To control the power, click on the appropriate button. During power cycling, the Power Status bar
will indicate the temporary status, with a blue background. Once the cycle is complete, the status
bar will revert to its original condition. To abort a power cycle, click on either Power On or Power
Off buttons. iBoot-G2 will assume the status selected.
If the AutoPing features is in use, the page will also display the current status, OK or Failed, for
each AutoPing used, with a counter of how many times it failed and how many times the Action was
triggered. If connecting with the Admin credentials, reset buttons for the Fail and Trigger counters
are provided.
To access the Setup page, the
administrator credentials must be
used for the initial login.
When you are finished with iBoot,
click on Logout. A confirmation page
will be displayed. If another user is
logged into the iBoot-G2, an In Use
page will be displayed.
Note: For command line and DxP Protocol please refer to the user manual
6 Setup
iBoot-G2 setup section consists of several pages. Access any page via the buttons on the left of
the page. Each time a setting is changed click on the Save button for that page to save the
changes before moving to the next page.
6.1 Device Configuration
1. Under the Device settings option set a device name and set the cycle time. This is the
length of time the power will be off during a reboot, or on during a power burst. Save
changes.
2. Under Network settings enter IP address information accordingly. You can also change
from standard port settings for HTTP, telnet and set auto log off here. Save changes.
3. The AutoPing feature will ping a periodically. Enter the details for addresses, frequency and
scalar here. Fail counter will determine how many fails are occurred before a cycle.
NOTE: Pinging addresses over the air interface will result in chargeable data being created.
NOTE: Changes to AutoPing settings will only take effect with a reboot.
4. Next set the mode of operation accordingly to the table on the next page. Select from AND,
OR or Single. With And, both AutoPings need to exceed their fail count to trigger the
Device Setup Page