S REGISTER SUMMARY
Register
Brief Description Defaults (Decimal
unless stated)
S0
®
Rings to answer. 2
S1 Ring count. 0
S2
®
Escape code character. 43
S3
®
Carriage return character. 13
S4
®
Line feed character. 10
S5
®
Back space character. 8
S6
®
Wait for dial tone. 2
S7
®
Wait for carrier after dial. 45
S8
®
Dial pause time for comma. 2
S10
®
Loss of carrier response time. 3
S12
®
Escape code guard time. 50
S14
®
Echo response codes verbose leased line dialling. 14 Hex
S21
®
CD control, dumb alarm mode, password, remote
configuration.
0
S23
®
Modulation, parity, guard tone, calling tone. 18 Hex
S30
®
MNP, CSI, result codes, make/break 08 Hex
S31
®
Flow control, break, pass through, remote loop. 01 Hex
S32
®
Xoff character. 19
S33
®
Xon character. 17
S36,37
®
Inactivity duration. 0
S50
®
Redial attempts. 5
S51
®
Delay before redialling. 3
S52
®
Delay before alarm message. 0
S53
®
MNP autoreliable delay. 0
NOTE:
®