User manual

Section 8
S REGISTERS
Copyright (C) Dataplex Pty Ltd
8-3
S0 Rings to Answer
Default : 2 (Answer on second ring)
Range : 0 to 255 (Stored in NVRAM)
Establishes the number of rings that the modem must receive before the auto answer
sequence is started. Values of 0 ensure the DPX-213 never answers (the value for
Originate Mode) while values from 1-255 will enable auto answer.
NOTE: When in leased line Mode, S0=0 forces the DPX-213 into Originate Mode and
S0=(1-255 but not zero) forces the DPX-213 into Answer Mode. For a point to
point leased line application, you must set ATS0=0 at one end and ATS0=1 to
255 at the other end; n must NOT be 0 at both ends.
S1 Ring Count
Default : 0
Range : 0 to 255
S1 is a read only register that is incremented every time an incoming ring signal is
detected. This register is automatically cleared if no ring is received within an 8 second
interval.
S2 Escape Code Character
Default : 43 Decimal (
+
; {2B HEX})
Range : 0-255
S2 contains the ASCII value of the escape code character. The escape code allows the user
to exit the on-line state and return to local command state.
S3 Carriage Return Character
Default : 13 Decimal (
###
m
; {0D HEX})
Range : 0-255
S3 contains the ASCII value of the Carriage Return character. This character serves as the
command line terminator.
S4 Line Feed Character
Default : 10 Decimal (
###
j
; {0A HEX})
Range : 0-255
S4 contains the ASCII value of the Line Feed character. The Line Feed character is output
after the Carriage Return character if full word (verbose) results are enabled (ATV1
command).