This document is uncontrolled when printed.
The program will come back
with: COMMAND
Enter filename:
type in 'lxr37.bin' and hit
return The program will come
back with:
Enter offset <diskfile> [0] : (hit return)
Use standard Algorithm ? [Y/n] : (hit return)
Programming will begin by doing a blank check of the EPROM,
the EPROM will be programmed with the file named name.bin,
then the EPROM will have it's contents verified. The whole
procedure takes just over 4 minutes on a 386SX computer. Do
not disturb the EPROM until the whole process is complete.
5. A label must be affixed to the window of the EPROM when it has
been programmed. This label must have written on it the date
and the software version number. The software version should be
R3.7 or later. Suitable labels can be obtained from most
newsagents.
6. Replace the EPROM or fit the new EPROM as per the
instructions in Section 4.