Specifications

RailCorp Engineering Manual — Signals — Equipment Manual
Cerberus Level Crossing Monitor Field Equipment Manual TMG E1261
© RailCorp Page 7 of 89
Issued August 2012 UNCONTROLLED WHEN PRINTED Version 2.1
1 Introduction
1.1 About This Publication
This document provides information for the maintenance of SCADA-2000 Cerberus Level
Crossing monitors.
This document is primarily intended to be read by staff involved with the testing,
commissioning and maintenance of the Level Crossing monitor equipment.
The ‘Cerberus’ level crossing monitor, monitors the status of a railway level crossing
warning system, logs events, reports warning or failure conditions to a central location
(Control Centre), and provides facilities to remotely test the level crossing battery supply.
In typical installations the following items are monitored and logged (some also have
alarms): track circuits, control relays, level crossing warning lamps, flasher units, power
supplies, batteries, associated signal control relays. The event logging retains the last
8,000 changes to; relay positions, analogue voltage changes and to changes in the
number of operating lamps. Typically this is equivalent to 120 crossing operations.
The level crossing monitor is designed and interfaced to the level crossing equipment in
such a way as to minimise the risk of it providing incorrect information in a manner that is
not obviously incorrect or reducing the integrity of the level crossing.
The level crossing monitor has been especially designed to be interfaced with Signal
Engineering standard signalling designs which are used throughout NSW. (See standard
signalling circuits in appendix C).
Maintenance staff can visit the level crossing monitor and download the logged
information and the unit’s status via a PC and serial cable or they can obtain the same
information remotely via modem from a remote site.
If the optional Control Centre system is implemented then the Control Centre
automatically interrogates the level crossing monitor sites and conducts battery tests.
This Control Centre provides an automatic monitoring and checking system for a number
of level crossing monitors.
1.2 Referenced and associated publications
The following Signal Engineering Specifications provide additional information to this
document and are available on the RailCorp Engineering Internet and Intranet.
Specification SPG 1033 Vital Indication Optoisolator.
Specification SPG 1260 Level Crossing Monitor Requirements
Specification SDG 001 Circuit Design Standards (standard signalling circuits)
The following superseded Signal Engineering Specifications provide additional
information to this document and are only available by request to RailCorp.
Specification 1068 Analogue to Digital Converter
Specification 1071 Level crossing monitor hardware
Specification 1072 Level Crossing monitor - backplane.
Specification 1073 Scada 2000 D12 - Individual Input Optoisolator
Specification 1074 8 way output optoisolator