Specifications

RailCorp Engineering Manual — Signals — Equipment Manual
Cerberus Level Crossing Monitor Field Equipment Manual TMG E1261
© RailCorp Page 17 of 89
Issued August 2012 UNCONTROLLED WHEN PRINTED Version 2.1
Input Optoisolator
Output Optoisolator
Cables
Interface relays
Battery test load resistor
Modem
Telephone line surge protection unit
Telephone line
The level crossing monitor - Hardware Block Diagram shows how all components of the
Level Crossing monitor are connected together. (Appendix D)
Signal Engineering, Standard circuits sheets X14 to X26 & X49, X 50 details the normal
method of connecting the level crossing monitor to the level crossing signalling
equipment. X50 Part 2/2 shows the normal method for connecting the level crossing
monitor with the Westinghouse SAFEFLASH unit. (see Appendix C)
2.2 Main Box
2.2.1 General
Check that the correct EPROM is inserted. EPROMs are labelled with LXMON R3.7 (or
later), and a date. The software in the EPROM should be version R3.7 or later. The
EPROM is fitted in U5.
CAUTION
The EPROMs have to be inserted in the correct orientation. The notch on
the EPROM socket should match the notch on the EPROM. If power is
applied to a board with the EPROM incorrectly inserted, it may damage the
EPROM or the I/O Board.
The following drawings detail the main box:
M08-865A Front Panel layout
M08-865B Rear Panel layout
M08-866 Surge circuit drawing
M08-864A Wiring
M08-864B Wiring.
M08-851/1 ADC circuit,
M08-851/2 ADC physical.
M08-862 Flasher interface Cables
CSSC SRA1016 Level Crossing Monitor unit assembly. Sheet 4
CSSC SRA1016 Level Crossing Monitor unit assembly. Sheet 5
CSSC SRA1022 V/Suppress PCB for SRA1016.