Specifications
RailCorp Engineering Manual — Signals — Equipment Manual
Cerberus Level Crossing Monitor Field Equipment Manual TMG E1261
© RailCorp Page 13 of 89
Issued August 2012 UNCONTROLLED WHEN PRINTED Version 2.1
• Low battery voltage indication from charger.
• Any other function that qualifies the operation of the Level Crossing (for example
approach signals HR and ALSR).
• Crossing normal relay.
• Pedestrian gates normal and reverse.
• Reset fault or warning.
• Output state of each flasher.
Other relays/contacts of interest e.g. Signal control relays, releasing switches.
1.9 Digital Outputs
The level crossing monitor has 8 digital outputs. The current state of these outputs is
indicated on the front panel of the level crossing monitor. These outputs are connected to
the 8-way Output Optoisolator which is used to drive the required external relays. This
output optoisolator switches a common positive and are suitable for operating relays. In
particular they are suitable to drive 12 volt BRB 930 series relays directly.
The Level Crossing monitor outputs are as follows:
1 Battery test
Used to control battery test relay.
2 No Fault
This output is ON when no fault condition has been detected with either the level
crossing monitor or the level crossing equipment. The fault indication remains until
reset. This output may be used in the future to control an external flashing beacon
which indicates healthy/faulty level crossing operation to the train driver or public
road users.
3 No Warning
This output is ON when no warning condition has been detected with the level
crossing equipment. The warning indication remains until reset.
4 System
This output operates in conjunction with the No Fault output. This output is ON
when a fault has been detected internally with the level crossing monitor unit. The
output remains on until the fault condition is fixed.
8 Battery
This output operates in conjunction with the No Fault and No Warning outputs. This
output is ON when a fault or warning condition has been detected with the level
crossing battery. The output remains on until the fault or warning condition has
been reset.
9 Lamp
This output operates in conjunction with the No Fault and No Warning outputs. This
output is ON when a fault or warning condition has been detected with the level
crossing lamps. This output remains on until the correct number of working lamps
is detected. It cannot be turned off until the correct number of lamps has been
detected running for at least 10 seconds.
10 Logic