Specifications
RailCorp Engineering Manual — Signals — Equipment Manual
Cerberus Level Crossing Monitor Field Equipment Manual TMG E1261
© RailCorp Page 12 of 89
Issued August 2012 UNCONTROLLED WHEN PRINTED Version 2.1
and Warning conditions must be cleared before cancelling this mode otherwise they will
be reported to the Control Centre.
Note that the maintenance disable feature is a part of the expression file and can be
disabled if required by modifying the expression file.
1.7.3 Codes reported to Control Centre
The level crossing monitor will report a Fault or Warning and one of the following codes
when it detects a change in the status of the crossing. These directly relate to the monitor
front panel indications discussed previously. But also include some additional information
by identifying some indications that are grouped on the front panel.
Code reported by Control Centre PC
Level Crossing Monitor, Status
Codes
Code 1 LAMP
Code 2 LOGIC
Code 3 SYSTEM
Code 4 BATTERY
Code 5 TEST
Code 6 COMMUNICATIONS FAIL
Code 7 SECURITY ALARM
Code 8 EMERGENCY SWITCHES
Code 9 No Train for 72 hours
Code 10 No Test for 36 hours
Code 11 Operating Too long
TRAIN DRAGGING EQUIPMENT DRAGGING EQUIPMENT
Note 1: Security Alarm is intended to be an alarm module installed at the level
crossing. In the future a number of level crossing locations may have alarms
fitted which can then report back via the level crossing monitor to the Control
Centre.
Note 2: Train Dragging equipment is intended to be an alarm that is activated by
Train Dragging detector equipment. It is a future option.
1.8 Digital Inputs
The Level Crossing monitor has 48 digital inputs that are logged and 8 digital inputs that
are not logged. Digital inputs are conditioned through a 12 volt 32 way Input Optoisolator
board. They are suitable for input voltages in the range of 9 volts to 20 volts DC. They
require a positive voltage for each individual input and a common negative for the Input
Optoisolator board.
The following digital inputs are normally connected to the Level Crossing monitor when
available at the particular Level Crossing:
• All track circuits that qualify the operation of the level crossing.
• Direction stick relays.
• The level crossing control and repeat relays.
• Test switch.
• Manual operating switch.
• Boom 85-90 degree state.
• Lights, Bell, Boom and Gates emergency switches.
• AC supply state.