Operator`s manual
A-Class 83
Advanced Entry Calibration (continued)
Step Action Displayed Message Comment
14
a) Place the media in the Media
Sensor. Record the sensor
reading and label it ‘P’
(paper).
b) Place the liner, mark, or
notch in the Media Sensor.
Record the sensor reading and
label it ‘G’ or ‘M’ (Gap or
Mark).
c) Remove all media. Record
the sensor reading and label it
‘E’ (Empty).
(See the example below.)
GAIN TRAN <yyy>
*08 <0 – 32>
- or, for reflective media:
GAIN REFL <yyy>
*08 <0 – 32>
!
Where ‘yyy’ is a numerical
value representing the current
sensor reading.
15
Press the
ESC
Key followed
by the
Key.
SENSOR LEVELS
The sensor readings must now
be entered into the printer.
Paper Gap (or Mark) Empty
For example, at Gain Number 8,
these were the sensor readings
for each of the media conditions.
(Actual readings will vary.)
198
084
014