Operator`s manual
A-Class 81
Advanced Entry Calibration (continued)
Step Action Displayed Message Comment
11
Two Parts, A & B:
Part A: Proceed according to
your media type:
Die-cut Media:
a) Remove a label or two
from the liner material.
b) Reinstall the media.
c) Place only the liner under
the sensor.
d) Position the Eye Mark
over the middle of the liner;
see Section 3.5.
Notched Media:
Position the Eye Mark over
the center of the notch; see
Section 3.5.
Reflective Media:
Position the Eye Mark over
the center of the black mark;
see Section 3.5. (The black
mark must be facing down.)
Part B: Press the
ENTER
Key to
select the Gain Number
(denoted by an ‘*’) and then
record the sensor reading
(‘yyy’) in your table as a TOF
Value.
Next, press the
Key to
increment the Gain Number.
Repeat Part B of this step to
find the TOF Value for each of
the Gain Numbers (00-32).
GAIN TRAN <yyy>
*00 <0 – 32>
- Or, for reflective media:
GAIN REFL <yyy>
*00 <0 – 32>
!!
!
Where ‘yyy’ is a numerical
value representing the current
sensor reading: useful in
locating the best sensor position.
Note: Never position the
sensor over a perforation when
recording a sensor reading.
Note: Do NOT move the position of the Media Sensor after it has been adjusted.