Operator`s manual

A-Class 79
5.1.3 Advanced Entry Calibration
Advanced Entry Calibration is an alternate calibration method for special-case media types. This is a two-
part procedure: (1) recording the sensor readings for the label using differing algorithms; and, (2)
selecting the best result, re-sampling, and then entering those values.
&
Advanced Entry Calibration will override all previous calibration settings. Use this method ONLY if the
Standard Calibration procedure has failed.
Follow the steps below to perform an Advanced Entry Calibration:
Step Action Displayed Message Comment
1
Turn ‘On’ the printer.
Wait until the printer
initializes (about six seconds).
CANNOT CALIBRATE
-Or-
UNCALIBRATED!
(Media should be loaded and
the ‘Sensor Type’ set.)
2
Press the
MENU
Key.
MEDIA SETTINGS
The Menu Window will appear.
3
Press the
ENTER
Key.
MEDIA TYPE
See Section 4.2.2 for menu
items.
4
Press the
Key to scroll
to ‘Sensor Calibration’.
SENSOR CALIBRATION
Press the
ESC
Key to abort
this procedure.
5
Press the
ENTER
Key.
PERFORM CALIBRATION
You are entering the calibration
submenu.
6
Press the
Key to scroll
to ‘Advanced Entry’.
ADVANCED ENTRY !
You are entering Advanced
Entry Calibration.
7
Press the
ENTER
Key.
SENSOR LEVELS
!!
Press the
ESC
Key to abort
this procedure.
8
Press the
Key.
SENSOR GAIN!
!
!
You are beginning the
Advanced Entry Calibration.