Operator`s manual

A-Class 77
Standard Calibration (continued)
Step Action Displayed Message Comment
7
Proceed according to the type
of media being calibrated:
Die-cut:
a) Remove a label or two
from the liner material.
b) Reinstall the media.
c) Place only the liner under
the sensor.
d) Position the Eye Mark
over the middle of the liner.
e) Press any key.
Notched:
a) Position the Eye Mark
over the center of the notch.
b) Press any key.
Reflective:
a) Position the Sensor Eye
Mark over the center of the
black mark. (The black mark
should face down in the
printer.)
b) Press any key.
Continuous:
Go to Step 8.
SCAN BACKING
PRESS ANY KEY <yyy>
!
- Or, for reflective media:
!
!
SCAN MARK
PRESS ANY KEY <yyy>!
!
!!
Sets the ‘gap’ (or ‘mark’) value
- where ‘yyy’ is a numerical
value representing the current
sensor reading.
Note: Never position a
perforation under the sensor
when recording a sensor reading.
8
Position a label (and backing, if
any) under the Eye Mark; see
Section 3.5.
Press any key to continue.
SCAN PAPER
PRESS ANY KEY <yyy>
!
!
This sets the parameter for the
‘paper’ value - where ‘yyy’ is a
numerical value representing the
current sensor reading.
Note: If using preprinted stock,
ensure that the label area under
the sensor is free of preprinted
text, graphics or borders.