Operator`s manual
76 A-Class
5.1.2 Standard Calibration
Perform the Standard Calibration when ‘Cannot Calibrate’ or ‘Uncalibrated’ is displayed. During the
process, the printhead assembly can be raised for visual access. In addition, displayed sensor readings can
be used to indicate the best position over the media, which is helpful when using small, position-critical
TOF notches or marks. Three readings are required:
• Empty: No media in the sensor.
• TOF Mark: Only the backing, notch, or reflective mark in the sensor.
• Paper: The label (with the liner attached) in the sensor.
Follow the steps below to perform a Standard Calibration:
Step Action Displayed Message Comment
1
Turn ‘On’ the printer.
Wait until the printer
initializes (about six seconds).
CANNOT CALIBRATE
-Or-
UNCALIBRATED
(Media should be loaded and
the ‘Sensor Type’ set.)
2
Press the
MENU
Key.
MEDIA SETTINGS
The Menu Window will
appear.
3
Press the
ENTER
Key.
MEDIA TYPE
See Section 4.2.2 for menu
items.
4
Press the
Key to scroll
to ‘Sensor Calibration’.
SENSOR CALIBRATION
Press the
ESC
Key to abort this procedure.
5
Press the
ENTER
Key.
PERFORM CALIBRATION
You are beginning the
calibration procedure.
6
Press the
ENTER
Key.
Remove the media from the
Media Sensor then press any
key.
!
REMOVE LABEL STOCK
PRESS ANY KEY <yyy>
Sets the ‘empty’ value - where
‘yyy’ is a numerical value
representing the current sensor
reading.