HEAT COMMAND
Allows the user to disable the DPL Heat Command, providing
compatibility with other DATAMAX printers.
ENABLED
Normal printer operating mode.
DISABLED
DPL Heat command is ignored. The heat value is controlled via the
menu setting; see Section 4.2.3.
SPEED COMMANDS
Allows the user to disable the DPL speed commands (Print, Feed,
Slew, and Reverse).
ENABLED
Normal printer operating mode.
DISABLED
DPL speed commands are ignored. The speeds are controlled via
the menu setting; see Section 4.2.3.
TOF SENSING COMMANDS
Allows the user to disable the DPL Top of Form commands (Gap,
Continuous, and Reflective).
ENABLED
Normal printer operating mode.
DISABLED
DPL TOF commands are ignored. The TOF is controlled via the
menu setting; see Section 4.2.2.
SYMBOL SET COMMAND
Allows the user to disable the DPL Single and Double Symbol Set
selection commands.
ENABLED
Normal printer operating mode.
DISABLED
DPL Symbol Set commands are ignored. The Symbol Set selection
is controlled via the menu setting; see Section 4.2.5.
CNTRL-CODES (DATA)
Allows the user to remove control codes (data < 20 Hex) from the
data fields. The selected line terminator is processed.
ENABLED
Normal printer operating mode.
DISABLED
DPL Control Code (SOH, STX, CR, ESC, and ^) functions are
ignored.
STX-V SW SETTINGS
Allows the user to disable the DPL software switch setting
commands.
ENABLED
Normal printer operating mode.
DISABLED
DPL option-enable command (<STX>V) is ignored.
MAX LENGTH COMMAND
Allows the user to disable the DPL maximum label length
command.
ENABLED
Normal printer operating mode.
DISABLED
The DPL <STX>M command is ignored. Maximum label length is
controlled via the menu setting; see Section 4.2.2.