Operator`s manual

120 A-Class
Electrical
Input Voltage: 90 – 132 / 180 – 264 VAC @ 47 – 63 Hz, auto-ranging
Grounding: Unit must be connected to a properly grounded circuit.
Power Consumption: A-4xxx models: 90 watts, typical operating / 10 watts, standby
A-6xxx models: 120 watts, typical operating / 10 watts, standby
Environmental
Operating Temperature:
40° F – 100° F (4°C – 38° C)
Storage Temperature:
-40°F – 150°F (-40° C – 60° C)
Relative Operating Humidity:
10% – 90% (non-condensing)
Relative Storage Humidity:
5% – 95% (non-condensing)
Electromagnetic Radiation: Moderate RF fields can be tolerated.
Dust:
Non-conducting, non-corrosive
Fonts (See Appendix B for examples.)
Resident: Nine alphanumeric fonts from .035 inch (.89 mm) to 16 inches (40.5
cm) and OCR-A and OCR-B; CG Triumvirate from AFGA® in
both Portrait and Landscape orientations (from 6 to 72 point).
Scalable:
CG Triumvirate and CG Triumvirate Bold Condensed, also
downloaded True Type formats.
Expansion: All fonts expandable vertically up to 24x.
Rotation:
Fonts (and graphics) can be printed in four directions: 0°, 90°, 180°,
270°.
Character Set: 66 Selectable Code Pages (PC_850 Multilingual set by default)
Note: CG Triumvirate and CG Triumvirate Bold Condensed Scaleable Fonts do not support the Unicode code
page.