Operator`s manual
A-Class 119
Specifications
Unless noted, the following specifications pertain to all A-Class models. References to the ‘A-4xxx’
denote the A-4212, A-4310, A-4408, and A-4606 models, while ‘A-6xxx’ denotes the A-6212 and A-
6310 models.
Bar Codes (See Appendix B for details.)
Code 39, Interleaved 2 of 5, Code 128 A, B & C, Codabar, UPC-A, UPC-E, UPC 2 & 5 digit addendums,
EAN-8, EAN-13, UCC/EAN Code 128 Random Weight, Code 93, MSI Plessey, Postnet, Telepen, UPS
MaxiCode, PDF417, DataMatrix, Aztec, QR Code, MicroPDF417, USD 8, RSS, UCC/EAN Kmart non
EDI, TLC39, EAN 128 w/auto subset switching, and Code 128 w/auto subset switching.
Note: Many bar codes carry trade names, yet they are composed of derivatives of a generic symbology
structure. If you have questions regarding a specific code not found in the list above, contact Datamax for
details.
Communications/Applicator
Interfaces:
(1) Serial, EIA RS-232 DB9 and RS-422/RS-485 (configurable)
(1) Parallel, IEEE 1284 Compliant
(1) USB, Version 1.1 Compliant
(1) Serial, EIA RS-232 DB9 (Aux Port – configurable)
(1) Applicator Interface (General Purpose Input/Output Port):
Signal Inputs: Optocoupled
Voltage Outputs:
+5 VDC, fused (resettable) @ 0.75 amps
+24 VDC, fused (resettable) @ 1.6 amps
Signal Outputs: Transistor @ 20 mA maximum sinking current.
Serial –
Data Rates: 1200, 2400, 4800, 9600, 19.2K, and 38.4K baud
Handshaking: Xon / Xoff; CTS / DTR
Parity: Even, Odd, or None
Stop Bits: 1 or 2
Data Bits: 7 or 8