Operator`s manual

80 A-Class Mark II
Step
Action Displayed Message Comment
K
In the table, where both
the Label Value and TOF
Value are at least 20,
subtract the amounts and
record the result as a
Difference Value (see
below).
Identify the largest
Difference Value and then
the corresponding Gain
Number.
GAIN TRAN
*31 (0 -
31)
<yyy>
- Or, for reflective media:
GAIN REFL
*31 (0 – 31)
<yyy>
In this example, Gain
Number 18 is chosen
because, where both values
are at least twenty, it has
the highest Difference Value.
This Gain Number will be
used to resample the media.
Sample Calibration Table
Gain Number Label Value TOF Value Difference Value
00 252 248 4
01 250 245 5
02 248 234 14
… … … …
15 188 63 125
16 184 51 133
17 179 38 141
18 174 25 149
19 170 19 N/A
… … … …
31 132 14 N/A
Step
Action Displayed Message Comment
L
Scroll to the Gain Number
determined in the
previous step and then
press the ENTER Key.
GAIN TRAN
*18 (0 -
31)
<yyy>
- Or, for reflective media:
GAIN REFL
*18 (0 – 31)
<yyy>
After ENTER is pressed, an
asterisk (*) appears to denote
selection.
(Continued)