User Manual
Extended System-Level Command Functions
Class Series Programmer’s Manual 59
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
Software Switch
SV
Y, N
Y = Processed
N = Ignored
Display-Equipped Communications N/A
Start of Print
EQ
3, 4
3 = Active Low,
4 = Active High
Display-Equipped Printer Options N/A
Non-Display 20
Stop Location
SL
A, H, P,
C, T, N
See Table 5-10.
Non-Display 16
N/A
Tear Position
PT
Y, N
Y = Enabled,
N = Disabled
Non-Display
(except EX2)
20 N/A
TOF Bias
[2]
TB
0 – 50 .1 Volt DC Non-Display 14 N/A
TOF Delta
[2]
TD
0 – 50 .1 Volt DC Non-Display 13 N/A
TOF Gain
[2]
TG
0 – 15 .1 Volt DC Non-Display 12 N/A
Table 5-1: Configuration Set Commands (continued)