Troubleshooting Field Procedure
The following steps should be taken to troubleshoot FIREFLY issues while in the field:
Perform a Walk-Up RV (see Read and Verify Procedure section of this manual).
If walk-up RV is accurate, proceed to the next meter on the Troubleshooting report.
If the FIREFLY is inaccurate or has any Trouble Codes then proceed with Troubleshooting.
Troubleshooting Details
Check the following before troubleshooting the FIREFLY:
The dials are not stuck or malfunctioning.
Make sure the FIREFLY has no visible damage.
Receiving no RF signal from a FIREFLY
When Interrogating a FIREFLY from a ROADRUNNER and no radio read can be made, check the following:
Check Current Settings to verify the register # on the meter, ROADRUNNER, and FIREFLY match.
Verify that in Current Settings of the FIREFLY, the Mode is showing to be ‘Active’.
Inaccurate Under-counting FIREFLY
Electric FIREFLY:
Check connection of FIREFLY to power posts. Reconnect using the proper technique if needed.
Confirm there are no reflective unpainted areas within the painted area of the disc.
Check meter disc speed; excessive disc spend can cause under-counting. Continually undercounting deltas usually
mean the account has an under-sized meter, making both the meter and FIREFLY miss counts.