User Manual

Table Of Contents
Datamatic, LTD. System Training Manual Version 08.24.12
- 44 -
Confidential Datamatic, Ltd. 2012
Connecting and Programming the Remote Shutoff Valve
Connecting the Remote Shutoff Valve
Connect the RSV wires with the MOSAIC FIREFLY using the wiring scheme below:
FIREFLY Wire
Remote Shutoff
Valve Wire
Green Green
Yellow White
Black Brown
FIREFLY
Blue
Red
Shorted together
See Installation Procedures section for detailed instructions and approved splicing methods.
NOTE: Remote Shutoff Valves should only be installed by a licensed plumber.
Programming the Remote Shutoff Valve
From the FIREFLY Menu, select option 3. Program by Parameter.
Enter FIREFLY Serial number and press Enter.
Select option 2. Meter ID. Verify that the Register/Meter number is correct that you are programming
into the FIREFLY:
The Meter ID can be up to 10 alphanumeric characters (16 characters may be used only if employing the
RS3 Import/Export record layouts).
Enter the Register/Meter (or FIREFLY Serial Number) number and press Enter.