User Manual
Table Of Contents
- MOSAIC™ regulations and Warranty information
- FCC Regulations
- Introduction
- Equipment
- Installation Considerations
- Installation Supplies
- FIREFLY Menu Screen
- Programming MOSAIC FIREFLYs
- Connecting the Remote Shutoff Valve
- Extract Profile Data
- Program GPS Coordinates
- Options
- Operate RSV
- Set Phy Fram
- Set FF To Ship Mode
- Upgrade Firmware
- Set FF Date/Time
- View Mesh Neighbors
- Set Radio Port
- Joining the MESH Network/LED Status
- General LED Information
- MOSAIC FIREFLYs Connected to an Encoded Meter (Mesh Mode)
- MOSAIC FIREFLYs Connected to a Pulse Meter (Mesh Mode)
- MOSAIC Sensor-end FIREFLYs (Mesh Mode)
- MOSAIC FIREFLYs as Repeaters (Mesh Mode)
- MOSAIC FIREFLYs in Non-Mesh Mode
- MOSIAC FIREFLYs on Encoded Meters (Non-Mesh Mode)
- MOSAIC FIREFLYs on Pulse Meters (Non-Mesh Mode)
- MOSAIC FIREFLYs (D411X only) Connected to Remote Shutoff Valves
- Troubleshooting Procedures
- Mounting the MOSAIC FIREFLY
- FAQ’s
- Can I use both MOSAIC Gateway backhaul types in a single installation?
- Why would I need to use GPRS in an installation?
- How many MOSAIC FIREFLYs can mesh together?
- What is the output power of a MOSAIC FIREFLY?
- What is the range of a MOSAIC FIREFLY?
- Are the new MOSAIC FIREFLYs compatible with previous legacy FIREFLYs?
- Do the MOSAIC FIREFLYs read via the ROADRUNNER MOBILE product?
- Will I need different MOSAIC FIREFLYS for Mesh and Mobile functionality?
- How do I program an MOSAIC FIREFLY?
- What does your handheld programming tool look like?
- What is the battery life for the MOSAIC FIREFLY?
- Is the battery pack replaceable?
- What frequency does the MOSAIC product use?
- Do you use a licensed frequency?
- Does your product provide profiling?
- How do you get the profiling?
- How often do I get reads via the Mesh?
- Is the system 2-way?
- What can I do with the 2-way functionality?
- Does the MOSAIC system have repeaters?
- How do the MOSAIC FIREFLY repeaters work?
- What is the MOSAIC FIREFLY repeater battery life?
- Do you support cellular backhaul from the MOSAIC Gateway?
- FIREFLY Template for_________________________________
- FIREFLY Template for_________________________________
- FIREFLY Template for_________________________________
- FIREFLY Template for_________________________________
- FIREFLY Template for_________________________________
- FIREFLY Template for_________________________________
- Support
- Consumables
- Return Material Authorizations (RMAs)
- Training and Support
Datamatic, LTD. System Training Manual Version 08.24.12
- 37 -
Confidential Datamatic, Ltd. 2012
MOSAIC FIREFLY with burial pod connecting to the register
Splice Methods
Water Pit Splice Method for Direct Register Connections:
• Strip the wires back.
• Cut excess wires and direct connect to meter according to wire connections guide per register
type.
• Fill the wire connection reservoir on the meter with DC-111.
Each register terminal and wire connection must be protected from moisture utilizing the Electrical
Insulating Compound Specified below:
DOW CORNING
MFG. Model # 111
Basement Splice:
• Space the connections out so that the Mastic Pad will cover the entire connection.
• The 3M Scotch Vinyl Mastic Pad can be cut so that one pad covers 2-3 installations depending
on the number of wires needed and type of connectors used.
• Be sure there is enough pad to completely cover the connections.
• Due to the nature of the Mastic Adhesive, this installation cannot be completed in temperatures
below 45 degrees Fahrenheit.
• Once the Mastic Adhesive is placed over the splice, it must be squeezed together and molded
around the splice to insure a watertight seal.
Mastic Pad