User Manual

Table Of Contents
Datamatic, LTD. System Training Manual Version 08.24.12
- 34 -
Confidential Datamatic, Ltd. 2012
MOSAIC-Class FIREFLY PULSE WIRING
Brand Model FF Wires Meter Wires Note Meter Type
Actaris Cyble Sensor Black White
Blue Brown
FF Red and Green
shorted together
4
AMCO Digital Pulse Black Red
Green Green
Blue Black
5
Badger RTR Black Black
Blue Red
FF Red and Green
shorted together
4
Badger RTR Black Black
(Pulse with tamper) Blue Red
Green Green
5
Corona Pulsar Green Green
(Pulse with tamper) Black Brown
Blue White
5
Corona Pulsar Black Brown
Blue White
FF Red and Green
shorted together
4
Hendey HPM Black Black
Performance PMN 05 Nitro 1 Blue Green
FF Red and Green
shorted together
4
Hendey PMN Black Black
Performance PMN 05 Nitro 1 Blue Green
FF Red and Green
shorted together
4
Kent/Elster V100 Black Blue
Blue Red
FF Red and Green
shorted together
4
Master Logical Switch Black Black
High Glass
Blue Red
FF Red and Green
shorted together
4
Master Pulse Black Black
Blue Red
FF Red and Green
shorted together
4
MOSAIC-Class FIREFLY REPEATER WIRING
All models except D4000 & D4110 Red
Blue
FF Red and Blue
shorted together
253
MOSAIC-Class FIREFLY to Remote Shutoff Valve WIRING
FF Wires RSV Wires
Green Green
Yellow White
Black Brown
FF Red and Blue
shorted together
19
MOSAIC-Class FIREFLY to PermaLog WIRING
FF Wires PLOG Wires
Red Red
Green Green
Black Black
3, 16, or 17
Schematics: Write in the Wire Color Combinations Below
MOSAIC FIREFLY
Meter
Schematics: Write in the Wire Color Combinations Below
MOSAIC FIREFLY
Meter
Schematics: Write in the Wire Color Combinations Below
MOSAIC FIREFLY
Meter
Schematics: Write in the Wire Color Combinations Below
MOSAIC FIREFLY
Meter