Remote Shutoff Valve
The Remote Shutoff Valve (RSV) is used in conjunction with the MOSAIC FIREFLY (D411X only) to
control water service termination, providing utilities with a convenient method to deploy water shut-off
service. The FIREFLY can issue commands to the RSV to Open, Close, or report its current status
(open or closed).
There are three software/firmware components to the RSV system. These are ROADRUNNER
software, radio firmware, and the FIREFLY firmware. To ensure proper functionality of any RSV, the
units should be loaded with the minimum software/firmware listed below:
ROADRUNNER CE 3.26.4
Radio firmware 1.3.20
FIREFLY D4110 firmware 1.5.2
Batteries: lithium battery pack with an output of 3.6V
Construction: brass plated ball-valve with a non-corroding compound; able to operate at a 150
psi pressure and compliant with AWWA Standard C700-02, section 4.2.9
Operating Temperature Range: -1 C to +60 C