User Manual

Datamatic, LTD. System Training Manual Version 08.14.09
- 40 -
Confidential Datamatic, Ltd. 2009
The software disconnects from the radio and then attempts to reconnect in order to verify that the radio
is working properly after the firmware image swap.
After the image swap is complete, the Load Firmware Image dialog is redisplayed along with the
updated OREO firmware images as shown in the following dialog:
Note that the primary and secondary firmware images have been swapped.
If the user loads an updated OREO firmware version to the OREO, when the user returns to the main
menu, the software will check the OREO version to verify it is compatible with the radio settings. This
is mainly due to the fact that 1.3.20 does not support communicating with MESH devices through the
binary interface. If the OREO firmware version is not compatible with the radio communication
settings, the settings will be automatically updated to match those supported by the OREO firmware.
The user will be notified when this occurs. The following dialog is an example:
NOTE: It is highly recommend updating the OREO firmware to version 1.5.12 immediately after
loading CXMI 1.3 to the hand held. CXMI 1.3 will be supplied with ROADRUNNER 3.26.3 and
3.26.4 bin files. OREO firmware version 1.5.12 is also supplied in these bin files.
Once the transfer has completed, the user will be returned to the list of available firmware images dialog
box. The firmware image was transferred to the secondary image on the OREO. If the image loaded is
to replace the existing OREO image, a boot swap command must be done to move the image to the
primary location.