MOSAIC FIREFLY with burial pod connecting to the register
Splice Methods
Water Pit Splice Method for Direct Register Connections:
• Strip the wires back.
• Cut excess wires and direct connect to meter according to wire connections guide per register
type.
• Fill the wire connection reservoir on the meter with DC-111.
Each register terminal and wire connection must be protected from moisture utilizing the Electrical
Insulating Compound Specified below:
DOW CORNING
MFG. Model # 111
Basement Splice:
• Space the connections out so that the Mastic Pad will cover the entire connection.
• The 3M Scotch Vinyl Mastic Pad can be cut so that one pad covers 2-3 installations depending
on the number of wires needed and type of connectors used.
• Be sure there is enough pad to completely cover the connections.
• Due to the nature of the Mastic Adhesive, this installation cannot be completed in temperatures
below 45 degrees Fahrenheit.
• Once the Mastic Adhesive is placed over the splice, it must be squeezed together and molded
around the splice to insure a watertight seal.
Mastic Pad