MOSAIC FIREFLY with burial pod connecting to the register
Splice Methods
Water Pit Splice Method for Direct Register Connections:
Strip the wires back.
Cut excess wires and direct connect to meter according to wire connections guide per register
type.
Fill the wire connection reservoir on the meter with DC-111.
Each register terminal and wire connection must be protected from moisture utilizing the Electrical
Insulating Compound Specified below:
DOW CORNING
MFG. Model # 111
Basement Splice:
Space the connections out so that the Mastic Pad will cover the entire connection.
The 3M Scotch Vinyl Mastic Pad can be cut so that one pad covers 2-3 installations depending
on the number of wires needed and type of connectors used.
Be sure there is enough pad to completely cover the connections.
Due to the nature of the Mastic Adhesive, this installation cannot be completed in temperatures
below 45 degrees Fahrenheit.
Once the Mastic Adhesive is placed over the splice, it must be squeezed together and molded
around the splice to insure a watertight seal.
Mastic Pad