User Manual
Datamatic, LTD. System Training Manual Version 08.14.09
- 30 -
Confidential Datamatic, Ltd. 2009
Be careful not to nick any individual wires when removing the insulated covering from the wires.
Connect the wires using UY gel cap connectors. If the wires are stripped, cut off the stripped ends.
Wires must have un-stripped ends for use in gel cap connectors. Use the Klein crimping tool to secure
the gel cap connectors. Do not use standard pliers to crimp UY connectors.
Make sure wires are fully seated – pull gently to verify that there is a secure connection.
MOSAIC FIREFLY with UY gel cap connectors to register
Note: Once connected to the encoded register, test the MOSAIC FIREFLY connections by swiping the
magnet under the LED’s to activate the MOSAIC FIREFLY.
After swiping, the MOSAIC FIREFLY will indicate a good connection to an encoded register by
displaying a solid red LED. Note, if the red LED does not go solid after attaching to an encoded register
the FIREFLY may not be connected correctly or the register cannot be read.
Pulse output registers do not provide instant feedback from the register after programming. A Read
Verification will need to be performed after installation to verify the meter is pulsing to the FIREFLY
properly. It is crucial to be sure the wires are connected properly prior to inserting them into the burial
pod.
After swiping, the MOSAIC FIREFLY will indicate a successful connection to a pulse register by
displaying a fast-blinking red LED. Insert the connections into the 3M burial pod.