MOSAIC-Class FIREFLY PULSE WIRING
Brand Model FF Wires Meter Wires Note
Meter
Type
Actaris Cyble Sensor Black White
Blue Brown
FF Red and Green
shorted together
4
AMCO Digital Pulse Black Red
Green Green
Blue Black
5
Badger RTR Black Black
Blue Red
FF Red and Green
shorted together
4
Badger RTR (Pulse with tamper) Black Black
Blue Red
Green Green
5
Kent/Elster V100 Black Blue
Blue Red
FF Red and Green
shorted together
4
Master Logical Switch Black Black
High Glass
Blue Red
FF Red and Green
shorted together
4
MOSAIC-Class FIREFLY REPEATER WIRING
All models except D4000 & D4110
Red
Blue
FF Red and Blue
shorted together
253