User's Manual
©
Datamatic, Ltd. 2007 - 19 -
Appendix A – Wire-end D4100 MOSAIC Connections - Encoded Meters
Brand Model Register Type FF Wires Meter Wires Comments
ABB/Kent Scancoder Encoded Red Green
Green Red
Black Black
Hersey Translator Encoded Red Red
Green Green 0109 +
Black Black
Master Meter Dialog Encoded Red Green
Green Green 0107 +
Black Red
Metron Prolink Encoded Brown Red
White Green
Black Black
Neptune T-8 Encoded Red 1 post
If dials have 2
cards
= ARB 5
Green 2 post
If dials have 3 cards,
can =
Black 3 post ARB 5 or ARB 6
Neptune AUTO Encoded Red Black
Green Red 0109 +
Black Green
Rockwell ECR Encoded Red Red
3 wire Green Green
Black Black
Rockwell ECR Encoded Red Red
2 wire Green Red
Black Black
Rockwell Touchread Encoded Red Red
3 wire Green Green
Black Black
Rockwell Touchread Encoded Red Red
2 wire Green Red
Black Black
Schlumberger ARB V Encoded Red Black
Green Red
Black Green
Schlumberger ARB VI Encoded Red Black
Green Red
Black Green
Schlumberger AUTO Encoded Red Black
Green Red 0109 +
Black Green
Sensus SR II Encoded Red Red
3 wire Green Green
Black Black
Sensus SR II Encoded Red Red
FF Red and Green
together