User's Manual

©
Datamatic, Ltd. 2007 - 17 -
DOW CORNING
Mfg. Model #: 4
Distributor: Grainger - Grainger item #: 6Y765
Unit of Measure: 5.3 oz. Tube
Basement Splice:
Connect D4100 MOSAIC wires to register cable wires using the UY connectors.
Space the connections out so that the Mastic pad will cover the entire connection.
The 3M Scotch Vinyl Mastic Pad can be cut so that one pad covers 2-3 installations depending on
number of wires needed and type of connectors used.
Be sure there is enough pad to completely cover the connections.
Due to the nature of the Mastic adhesive, this installation cannot be completed in temperatures below
45 degrees Fahrenheit.
Once the Mastic adhesive is placed over the splice, it must be squeezed together and molded around
the splice to insure a watertight seal.
Below is an illustration of the wire connections with the Mastic adhesive: