Datamatic, Ltd. 2007 - 17 -
DOW CORNING
Mfg. Model #: 4
Distributor: Grainger - Grainger item #: 6Y765
Unit of Measure: 5.3 oz. Tube
Basement Splice:
• Connect D4100 MOSAIC wires to register cable wires using the UY connectors.
• Space the connections out so that the Mastic pad will cover the entire connection.
• The 3M Scotch Vinyl Mastic Pad can be cut so that one pad covers 2-3 installations depending on
number of wires needed and type of connectors used.
• Be sure there is enough pad to completely cover the connections.
• Due to the nature of the Mastic adhesive, this installation cannot be completed in temperatures below
45 degrees Fahrenheit.
• Once the Mastic adhesive is placed over the splice, it must be squeezed together and molded around
the splice to insure a watertight seal.
Below is an illustration of the wire connections with the Mastic adhesive: