User's Manual
- 16 -
©
Datamatic, Ltd. 2007
• Snap the burial pod shut and allow 30 minutes of drying time.
Below are examples of approved Burial Pods that can be used with the Wire-end D4100 MOSAIC:
3M Direct Burial Splice Pod UY connector/Burial pod combination
Firmware 011 & 0111 Firmware 0106-0109
Below is an illustration of the water pit splice method including the meter and D4100 MOSAIC:
Water Pit Splice Method for Direct Register Connections:
• Strip the wires back 4 inches.
• Cut excess wires and direct connect to meter according to wire connections guide per register type.
• Pod remaining wires in black pod and fill with epoxy per approved method.
Each register terminal and wire connection must be protected from moisture utilizing the Electrical
Insulating Compound specified below.