Final Optic Sensor-end D4100 MOSAIC Installation Steps
1. A full cure on the seal is achieved in 24-96 hours. Do not touch, pull, move, or handle the sensor in
any way during this period.
2. Mount the D4100 MOSAIC box with the threaded neck pointing up.
3. Mounting can be accomplished by attaching to a wall, stake, or through a hole in the meter box or
vault.
4. Typical meter pits will use an 18” long ¾” PVC stake. Push the stake into the ground approx. 6”
deep, adjacent to the meter register.
5. Attach the D4100 MOSAIC to the stake with the zip ties (6” or 14”).
6. If utilizing a lid lock, make certain not to over-tighten the D4100 MOSAIC within the lock.
7. Check for lid clearance; be sure to never rest the weight of the meter lid on the D4100 MOSAIC.