Operating temperature
-40° C to +85° C.
Operating voltage 3.6 VDC.
Sensor Magnetic
Radio communications
FCC Part 15. 902-928MHz ISM band .
Data rate 9600bps 1-way, 19200bps 2-way.
Radiated power .75 mW
Note: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates, uses and radiates radio frequency energy. If
not installed and used in accordance with the instructions, it may cause
harmful interference to radio communications. There is no guarantee that
interference will not occur in a particular installation.
If this equipment causes interference to radio or television reception, as
determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following
measures:
! Reorient or relocate the receiving antenna.
! Increase the separation between the equipment and the receiver.
! Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help
Profile Data Extraction for Gas and Electric
FIREFLYs
This same process occurs if communication is broken; the user is asked to retry
extraction.
For 0400 firmware 2-way Gas and 0020 firmware 2-way Electric FIREFLYs, the user
will be able to select how much profile data is desired during profile extraction.
The software will determine the number of available data bins and display the following
screen to allow the user to select the number of days of profile data to extract: