5. If the lid has a hole for the unit, use the
cap and wing nut assembly (“lid lock”
pictured at right). Ensure that enough
space exists between the box lid and
the ground for the unit to sit. If not,
remove some of the dirt from the
bottom of the box. Do not over-
tighten lid locks.
Water FIREFLY Installation
Installing the Optical Sensor-End FIREFLY
Meter Preparation
1. Remove meter box lid.
2. Survey the meter, checking lid, hole depth, and overall cleanliness.
3. Check for meter disqualification’s and enter the corresponding skip code.
4. Clean excess dirt from meter lid, exposing meter number and verify it with the
account on the ROADRUNNER.
5. Flip lid back and pre-clean meter face/lens using Fast Orange non-pumice cleaner
and a cloth or cotton swab to remove residue.
6. Clean meter face/lens with an isopropyl alcohol and a NEW lint-free cotton swab.
Note: Use Isopropyl rubbing alcohol, 99% by volume, for best results.
Lower concentrations do not clean as well and adversely affect the
sensor-to-meter bond.
7. Re-wipe the surface of the meter lens with a clean, new cotton swab each time until
the swab comes up clean, and the clean lens squeaks when wiped.
8. After cleaning, ensure that the lens is completely dry; allow time for the alcohol to
evaporate
Background Check
1. Connect the ROADRUNNER to the FIREFLY via the PPU.
2. On the 860 ES ROADRUNNER Press SHIFT I to display the FIREFLY main
menu and on the ROADRUNNER X7 press F5 .
3. Press A to begin testing the FIREFLY optics.