6. Choose one of the following three options to connect the wires to the 240VAC
terminals on the meter.
n Option A. Use fuse clip to attach wires to the 240VAC terminals on the meter.
n Option B. Use soldering to attach two wires to the 240VAC terminals on the
meter.
n Option C. Use female insulated crimp connector to connect the wires to the
240VAC terminals on the meter.
Note: If connectors are used in place of soldering, use UL-certified
crimper.
Fuse clip option Solder wires option Insulated crimp connector option
Note: The FIREFLY requires 240VAC during programming for the
settings to be written to its memory.
7. Power the meter with 240VAC or power the FIREFLY using between 5 and 12 volts
applied to the external battery jack.
8. Zero out the register.