Installing the Electric FIREFLY
1. Remove nameplate.
2. Position the unit on top of the nameplate posts.
3. Mount the unit flush on top of the nameplate posts with the spacer and nameplate
above it.
4. Thread the mounting screw through the nameplate, the 0.25-inch spacer, (
see
following illustration
), and
FIREFLY
into the nameplate post holes.
5. Adjust play in mounting holes so that
FIREFLY
is parallel with disk and the distance
between sensor face and disk is between 0.070 and 0.110 inches.
6. Choose one of the following three options to connect the wires to the 240VAC
terminals on the meter.
!
Option A. Use fuse clip to attach wires to the 240VAC terminals on the meter.
!
Option B. Use soldering to attach two wires to the 240VAC terminals on the
meter.
!
Option C. Use female insulated crimp connector to connect the wires to the
240VAC terminals on the meter.
Note: If connectors are used in place of soldering, use UL-certified
crimper.
Fuse clip option Solder wires option Insulated crimp connector option