8. Apply approved adhesive around the sensor to seal it completely if the pit fills with
water prior to the 24 - 96 hour cure time, or if the meter face is curved and not flat.
Note: If the sensor is initially misplaced, do not attempt to remove the
sensor by twisting the sensor body. A fully cured sensor requires
breaking the seal at the adhesive tape joint with a flat tool such as a
screwdriver. Insert the screwdriver between the aluminum base and
meter lens and twist.
9. Mount the
FIREFLY
MIU to an appropriate wall, stake or through hole in meter
box/vault lid.
If using a stake, affix the stake in the ground adjacent to the meter register. The
platform area of the pole needs to face inward.
Position the transmitter on the pole platform.
Attach the transmitter to the pole with the binding material.
If utilizing a lidlock, make certain Not to overtighten the FIREFLY within the lock.
Also be sure to never rest the weight of the lid on the FIREFLY.
10. Place sensor flap over sensor, insuring a snug fit.
11. Program the MIU and set to "Autocal".
12. Before closing the lid, make sure a visual meter reading is entered for the account.
Note: At this point, if sensor flap must be lifted to retrieve the visual
meter reading, AutoCal must be reset through the FIREFLY menu #7.
Installing the Wire-end
1. Refer to Appendix C “Meter Qualification” on page Error! Bookmark not defined.
to determine wire connection for the brand and model of meter.
2. Connect
FIREFLY
wire-end to meter contacts using Posi-lock connector or Gel caps.
3. Use 3M mastic pads to cover the wire connections. Ensure that the mastic pad forms
a complete seal around the wire connections.
4. Mount the
FIREFLY
to an appropriate wall, stake, or through hole in the meter box /
vault lid.
5. If using a stake, affix the stake in the ground adjacent to the meter register. The
platform area of the pole needs to face inward.
6. Position the transmitter on the pole platform.
7. Position the
FIREFLY
MIU with the threaded neck pointing up.
8. Attach the transmitter to the pole with the binding material.
Note: Do not connect a multi-meter, probe or other interrogating device
to the
FIREFLY
wires. Doing so may cause the unit to globally reset,
erasing all programmed data!