Quick Reference Guide
Table Of Contents
- Gryphon™ I GBT/GM4500
- Table of Contents
- END USER SOFTWARE LICENSE AGREEMENT
- About the Scanner
- Setting Up the Reader
- Reader, Cradle and LEDs Description
- Connecting the Base Station
- System and Network Layouts
- Using the GBT/GM4500 Scanner
- Using the WLC4090 Radio Base
- Replacing the Battery Pack
- Using the Gryphon™ I GBT/GM4500
- Linking the Reader
- Link Scanner as Serial Device to a Bluetooth Host
- Link Scanner as HID device to a Bluetooth host
- Power Off
- Selecting the Interface Type
- Programming
- Reading Parameters
- Operating Modes
- Technical Features
- LED and Beeper Indications
- Troubleshooting
- Ergonomic Recommendations
- Cleaning Procedure
- Support Through the Website
- Charging the Batteries
- Datalogic Limited Factory Warranty
Operating Modes
Quick Reference Guide 35
Operating Modes
Scan Mode
The imager can be set to operate in one of several scanning
modes. See the PRG for more information and settings for
any of the options:
Trigger Single (Default)
This mode is associated with typical
handheld reader operation. When the trigger is pulled, illumi-
nation is turned on and the scanner attempts to read a label.
Scanning is activated until one of the following occurs:
• the programmable “maximum scan on time”
1
has elapsed
• a label has been read
• the trigger is released
Trigger Pulse Multiple
Scanning begins when the trigger is
pulled and continues after the trigger is released, until the
trigger is pulled again or until the programmable “maximum
scan on time”
1
has elapsed. Reading a label does not disable
scanning. Double Read Timeout
1
prevents undesired multi-
ple reads while in this mode.
Trigger Hold Multiple
When the trigger is pulled, scanning
starts and the product scans until the trigger is released or
“maximum scan on time”
1
has elapsed. Reading a label does
not disable scanning. Double Read Timeout
1
prevents unde-
sired multiple reads while in this mode.
Always On
The illuminator is always ON and the reader is
always ready for code reading. Double Read Timeout
1
pre-
vents undesired multiple reads.
Flashing
The reader illuminator flashes on and off regardless
of the trigger status. Code reading takes place only during
the Flash On
2
time. Double Read Timeout
1
prevents unde-
sired multiple reads.
Object Detection
The scanner looks for changes within its
field-of-view. The Aiming Pattern is always on to show the
optimum reading area. If a predefined amount of movement
is detected, the white illumination switches on. Scanning
continues until a label is read or "maximum scan on time" is
reached.
1. See the Product Reference Guide (PRG) for these and other program-
mable features
2. Controlled by Flash On Time and Flash Off Time. Use the PRG to
program these options.










