PowerScan™ M8300 Readers Industrial Handheld Laser Bar Code Reader with Datalogic’s STAR Cordless System™ Quick Reference Guide
Datalogic ADC, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 ©2007-2014 Datalogic, Inc. An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic ADC, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic ADC").
Table of Contents Updates and Language Availability .............................................................. 1 Using PowerScan™ M8300 ............................................................................. 2 Scan Line Position .................................................................................. 2 Reading Angle ......................................................................................... 2 Aiming System ....................................................................
NOTES
UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentation updates for this product are available on the Datalogic website at www.datalogic.com. I Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Collegarsi a : www.datalogic.com F Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet. Cliquez sur : www.datalogic.
Using PowerScan™ M8300 USING POWERSCAN™ M8300 The PowerScan™ M8300 series readers can be used with either an BC-80X0 cradle or Stargate™ radio base station to build a Cordless Reading System for the collection, decoding and transmission of barcoded data. PowerScan™ M8300 laser readers automatically scan barcodes at a distance. Simply aim and pull the trigger. SCAN LINE POSITION Code scanning is performed along the scan line emitted from the reading window. This line must cross the entire code.
Using PowerScan™ M8300 AIMING SYSTEM PowerScan™ M8300 provides an aiming system. If enabled, a partial trigger press produces a red spot, which should be aimed over the code center to get the best reading performance, see figure (1) above. By completely pressing the trigger the scan line appears to start the code scanning (2).
Charging the Batteries CHARGING THE BATTERIES Once the BC-80X0/C-8000 is powered, you can charge the reader's batteries. Place the PowerScan™ M8300 into the BC-80X0 cradle or the C-8000 battery charger. The "Reader" LED on the cradle/battery charger turns red. The battery is completely charged when the "Reader" LED on the cradle/battery charger turns green. To change the batteries, unscrew the retaining screw and extract the battery pack from the reader handle.
Charging the Batteries BATTERY SAFETY To install, charge and/or perform any other action on the battery, follow the instructions in this manual. WARNING Do not discharge the battery using any device except for the scanner. When the battery is used in devices other than the designated product, it may damage the battery or reduce its life expectancy. If the device causes an abnormal current to flow, it may cause the battery to become hot, explode or ignite and cause serious injury.
Charging the Batteries CAUTION Do not place the battery in microwave ovens, high-pressure containers or on induction cookware. Immediately discontinue use of the battery if, while using, charging or storing the battery, the battery emits an unusual smell, feels hot, changes color or shape, or appears abnormal in any other way. Do not replace the battery pack when the device is turned on. Do not remove or damage the battery pack’s label. Do not use the battery pack if it is damaged in any part.
Charging the Batteries SETUP PowerScan™ M8300/BC-80X0 Point-to Point Configuration 1. Connect a BC-80X0 cradle to the Host. For installation and connection information see the BC-80X0 Quick Reference Manual. 2. Charge the PowerScan™ M8300 battery using an BC-80X0 or the C-8000 charger as described in this Quick Reference manual. A full charge takes 4 hours if using an external power supply; while it takes up to 10 hours if supplying power through the USB port. 3.
PowerScan™ M8300 Configuration POWERSCAN™ M8300 CONFIGURATION POWERSCAN™ M8300/BC-80X0 POINT-TO-POINT SETUP A rapid configuration procedure has been devised for point-to-point applications where a single reader is associated exclusively with its own BC-80X0 base station and where it is not necessary to set the Date and Time parameters.
PowerScan™ M8300 Configuration POWERSCAN™ M8300/BC-80X0 STAND ALONE SETUP When the BC-80X0 cradle is connected and powered, configure the PowerScan™ M8300 by reading the following codes in the given sequence and follow the instructions. Note: for the numeric code selection of steps 3, 4, and 5 use the table at the end of this Quick Reference. 1. Restore PowerScan™ M8300 Default Ì$+$*oÎ 2. Enter Configuration Ì$+;Î 3. Set Date ÌIA%Î + six digits for Day, Month and Year (DDMMYY). 4.
PowerScan™ M8300 Configuration 7. Read the Bind code to pair the PowerScan™ M8300 to the BC-80X0 cradle. The reader is dedicated to the cradle. Any previously bound reader will be excluded. To connect several readers to the same cradle see the following section "Using Multiple Readers with Same Cradle". Bind Ì$+RN0$-IÎ The green LED on the PowerScan™ M8300 will blink: the reader is ready to be positioned onto the cradle. 8.
PowerScan™ M8300 Configuration USING MULTIPLE READERS WITH SAME CRADLE If you want to use several readers associated with the same cradle, you must first Bind the cradle with one of the readers (see previously described configuration procedure). Successive readers can be associated with the same cradle by following the configuration procedure substituting the Bind command with Join. 7. Join Ì$+RN1$-NÎ The green LED on the PowerScan™ M8300 will blink: the reader is ready to be positioned onto the cradle.
PowerScan™ M8300 Configuration POWERSCAN™ M8300/STAR-SYSTEM™ SETUP The following procedure allows configuring a PowerScan™ M8300 reader to communicate with various STAR-System™ devices such as Stargate™ RF base stations: 1. Restore PowerScan™ M8300 Default Ì$+$*oÎ 2. Enter Configuration Ì$+;Î 3. Set Date ÌIA%Î + six digits for Day, Month and Year (DDMMYY). 4. Set Time ÌIB'Î + four digits for Hours and Minutes (HHMM). 5.
PowerScan™ M8300 Configuration 6. Set Radio Address ÌRF8Î + four digits from the Numeric Table for the PowerScan™ M8300 Address (from 0000 to 1999). All readers used in the same area must have different addresses. 7. Set First STAR-System™ Address ÌRSRÎ + four digits from the Numeric Table in the range 0000 to 1999 8.
PowerScan™ M8300 Default Configuration POWERSCAN™ M8300 DEFAULT CONFIGURATION DATA FORMAT code identifier disabled, field adjustment disabled, code length not transmitted, character replacement disabled CODE SELECTION enabled codes • EAN 8/EAN 13 / UPC A/UPC E without ADD ON check digit transmitted, no conversions • Interleaved 2/5 check digit control and transmission, variable length code; 4-99 characters • Standard Code 39 no check digit control, variable length code; 1-99 characters • Code 128 variable
Technical Features TECHNICAL FEATURES Electrical Features Battery Type 2150 Li-Ion battery pack Time of recharge max. 4 hours with external power supply max. 10 hours with Host power Operating autonomy (continuous reading) 60,000 reads (typical) Display (Only available models) with some Indicators LCD 4 lines x 16 chars Programmable font and backlight Good Read LED green Good Read Spot green Beeper Laser Features M8300 M8300-AR Power (max) in mW 0.9 mW 1.
Reading Tables READING TABLES PowerScan™ M8300 mil Typical reading distance with good quality codes 5 2.1 - 13.3 cm / 0.8 - 5.2 in 7,5 3.5 - 24.2 cm / 1.4 - 9.5 in 10 2.9 - 42.8 cm / 1.1 - 16.8 in 13 2.3 - 55.1 cm / 0.9 - 21.7 in 20 6.3 - 78.5 cm / 2.5 - 30.9 in 40 2.5 - 97.8 cm / 1.0 - 38.5 in PowerScan™ M8300 AR mil Typical reading distance with good quality codes 7,5 18 - 50 cm / 7.0 - 19.7 in 10 18 - 85 cm / 7.0 - 33.5 in 15 15 - 165 cm / 5.9 - 65.0 in 20 12 - 210 cm / 4.
Datalogic ADC Limited Factory Warranty DATALOGIC ADC LIMITED FACTORY WARRANTY WARRANTY COVERAGE Datalogic warranties this product against defects in workmanship and materials, for a period of 3 years from the date of shipment, provided that the product is operated under normal and proper conditions. Datalogic ADC ("Datalogic") hardware products are warranted against defects in material and workmanship under normal and proper use.
Datalogic ADC Limited Factory Warranty WARRANTY EXCLUSIONS The Datalogic Factory Warranty shall not apply to: (i) any product which has been damaged, modified, altered, repaired or upgraded by other than Datalogic service personnel or its authorized representatives; (ii) any claimed defect, failure or damage which Datalogic determines was caused by faulty operations, improper use, abuse, misuse, wear and tear, negligence, improper storage or use of parts or accessories not approved or supplied by Datalogic
Service and Support SERVICE AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to www.datalogic.com and click on the links indicated for further information including: • PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities including: - • • Datalogic Aladdin™, a multi-platform utility program that allows device configuration using a PC.
Compliance COMPLIANCE This device must be opened by qualified personnel only. The batteries must be removed before opening the device. FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules.
Compliance laser beam hits the eye of an observer, even through reflective surfaces such as mirrors, etc.
22 X X X ⬉䏃ᵓ㒘ӊ ܝᄺ㒘ӊ ܝᄺ㒘ӊ Printed Circuit Board Assembly Assy, Optics Block Assy, Module O O O ᳮ Mercury (Hg) O O O 叏 Hexavalent Chromium (Cr(VI)) Polybrominated biphenyls (PBB) O O O ચ卲 O O O ᄙᄽ侶 Ქኂ‛凝ᚗర⚛ Cadmium (Cd) O O O ᄙᄽԲㅘ Polybrominated diphenyl ethers (PBDE) O ઍᱝẊㇱઙ⊛ᚲဋ凝ޗறխࢬܶऱ具Ẋڶڶ୭ढ凝݁܅Պխ䦀Գا٥ࡉ㧺ॾஒ䣈䢓ຝᚲ咒ؒ⊛ ޝ䶣ॾஒ䣈խڶڶ୭ढ凝ऱૻၦޣρ(SJ/T 11363-2006) 億ࡳऱૻၦޕ X: ઍᱝẊㇱઙᚲ↪⊛ဋ凝ޗறխ, ⥋ዋ৻㮕᧚ᢱᚲ⊛Ქኂ‛凝Պխ䦀Գا٥ࡉ㧺ॾஒ䣈䢓ຝᚲ咒ؒ⊛ ޝ䶣ॾஒ䣈խڶڶ୭ढ凝ऱૻၦޣρ(SJ/T
Quick Reference Guide X X ㇱઙฬ⒓ ⬉䏃ᵓ㒘ӊ ܝᄺ㒘ӊ Printed Circuit Board Assembly Assy, Module O O 叏 Hexavalent Chromium (Cr(VI)) Polybrominated biphenyls (PBB) O O ચ卲 O O ᄙᄽ侶 Ქኂ‛凝ᚗర⚛ Cadmium (Cd) O O ᄙᄽԲㅘ Polybrominated diphenyl ethers (PBDE) O ઍᱝẊㇱઙ⊛ᚲဋ凝ޗறխࢬܶऱ具Ẋڶڶ୭ढ凝݁܅Պխ䦀Գا٥ࡉ㧺ॾஒ䣈䢓ຝᚲ咒ؒ⊛ ޝ䶣ॾஒ䣈խڶڶ୭ढ凝ऱૻၦޣρ(SJ/T 11363-2006) 億ࡳऱૻၦޕ X: ઍᱝẊㇱઙᚲ↪⊛ဋ凝ޗறխ, ⥋ዋ৻㮕᧚ᢱᚲ⊛Ქኂ‛凝Պխ䦀Գا٥ࡉ㧺ॾஒ䣈䢓ຝᚲ咒ؒ⊛ ޝ䶣ॾஒ䣈խڶڶ୭ढ凝ऱૻၦޣρ(SJ/T 11363-2006) 億ࡳऱૻ㊂ O O ᳮ 卋 PART Mercu
Compliance Cofetel Mexico Statement Cofetel Mexico Update Este producto es usable en México. Certificado Nr. RCPDAST08-0269 (COFETEL). BRAZILIAN CERTIFICATION STATEMENTS PM8300 (01)07898916345048 “Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário.
Compliance WEEE COMPLIANCE Waste Electrical and Electronic Equipment (WEEE) Statement English For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.datalogic.com. Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.datalogic.com. French Pour toute information relative à l’élimination des déchets électroniques (WEEE), veuillez consulter le site Internet www.datalogic.
Numeric Table NUMERIC TABLE Ì01Î 0 Ì12Î 1 Ì23Î 2 Ì34Î 3 Ì45Î 4 Ì56Î 5 Ì67Î 6 Ì78Î 7 Ì89Î 8 Ì9:Î 9 26 PowerScan™ M8300
DECLARATION OF CONFORMITY 13 Datalogic ADC Srl, Via S. Vitalino, 13 Lippo di Calderara di Reno (BO) 40012 Italy EC-054 Rev.: 4 Pag.
www.datalogic.com ©2007-2014 Datalogic, Inc. • All rights reserved. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. Datalogic ADC, Inc.