Enter Configuration Exit and Save Configuration
Ì$+;Î
CODE SELECTION
Ì$
-
?Î
Example:
The following string allows reading and transmitting with ADD ON all EAN/UPC starting with the
434/439, 977 and 978 prefixes:
1. EAN/UPC Autodiscrimination ADD ON by Prefix.
2. 434/439: enables reading and transmission with ADD ON of all EAN/UPC barcodes
starting with 434/439 prefixes.
3. 977: enables reading and transmission with ADD ON of all EAN/UPC barcodes starting
with 977 prefix.
4. 978: enables reading and transmission with ADD ON of all EAN/UPC barcodes starting
with 978 prefix.
EAN/UPC Autodiscrimination ADD ON by
Prefix
434/439
ÌAA8Ad19Î
+
ÌET3434ET4439ÉÎ
+
977 978
+
ÌET7977QÎ
+
ÌET8978ZÎ
To clear the current prefix selections:
1. Cancel all Selections
Cancel All Selections
ÌET0wÎ