Specifications

RS-232/USB-Com Interfaces
52 QuickScan
TM
Lite QW2100
ENTER/EXIT PROGRAMMING MODE
Enable Character
Specifies the value of the RS-232 host command used to enable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected. See
Enable Character on
page 256
for more detailed programming instructions.
NOTE
Setting to previously defined characters such as XON,
XOFF, or host commands conflicts with normal opera-
tion of these characters. 8-bit data is not recognized
when the option
Data Bits has been set as 7 Data Bits.
$CR2EC
Select Enable Character Setting
DEFAULT
0x45 = Enable Character is ā€˜E’